Dayton Operating Instructions and Parts Manual
Dayton
®
Wet/Dry Vacuums
3VE22, 4TB87A, 1UG91C and 2RPD8
immediately upon completing a wet pick up job or
when tank is full and ready to be emptied, raise
the hose to drain any excess liquid into the tank.
The interior of the tank should be periodically
cleaned. The foam sleeve should be cleaned
periodically as described in the following steps:
1. Always disconnect the plug from the wall
receptacle before removing the tank cover.
Remove foam sleeve by sliding it up and off
the lid cage.
2. Shake excess dust off sleeve with rapid up
and down movement.
3. Hold sleeve under running water rinsing
from the inside. A water wash is not always
required, depending on the condition of the
sleeve.
4. Gently wring out excess water, blot sleeve
with a clean towel and allow foam sleeve
to dry. The foam sleeve is now ready to be
re-installed on the lid cage.
NOTE: Bottom of sleeve should be TUCKED
in groove between lid cage and tank lid
(Figure 37).
NOTE: Wet pick up accessories should be
washed periodically with soap and water,
especially after picking up wet, sticky liquids.
Picking up detergent or cleaners that create foam
or suds can defeat the vacuums filtration. This
could cause foreign material
to pass into the motor
impeller area and shorten
motor life. This is not normal
use and is not covered by
product warranty.
WET PICK UP AND
PUMP ASSEMBLY OPERATION (For
model 4TB87A only)
TO REDUCE THE RISK OF ELECTRICAL
SHOCK, DO NOT DIRECT DISCHARGE
STREAM AT UNIT!
1. Always disconnect the plug from the wall
receptacle before removing the tank cover.
2. Remove tank cover and cartridge filter. Tank
should also be cleaned of any dirt or debris.
3. Ensure that the foam sleeve is in
place for wet pick up. (See Wet Pick Up
Operation)
4. Make sure inlet deflector is fully inserted into
deflector guide on inside of tank.
5. Insert tube provided into pick up cage pushing
until tube comes to a stop (Figure 38).
6. Take pick up assembly and insert tube into
hole in bottom of lid cage pushing until
assembly comes to a stop (Figure 39).
NOTE: Do not attempt to pump without pick
37
up cage in place or screen on pick up cage.
Failure to do this could result in damage to
pump.
7. Replace tank cover and secure lid latches.
8. To prevent unwanted discharge of water leave
cap in place or attach garden hose to unit
until you are ready to empty tank.
9. Once you are ready to begin pumping, remove
outlet fitting cover and connect a standard
garden hose (not supplied) to outlet fitting
(Figure 40).
10. Attach the 2½" hose to tank inlet.
11. Your vacuum is supplied with a wet pick up
elbow. Place the elbow on the hose end and
attach desired accessory to elbow (Figure
41). Elbow MUST be in place during wet
pick up to prevent overfilling of unit. Do not
attempt wet pick up without elbow in place.
Do not cover bleed hole in elbow. Failure
to follow these precautions will result in
overfilling of unit and misting through exhaust
port.
THE CARTRIDGE FILTER IS NOT COMPATIBLE
WHEN UTILIZING THE PUMP PICK UP
ASSEMBLY.
12. Plug vacuum in and push the ON switch.
13. Start wet pick up. In order to prime the pump
feature, you will need at least 4" of water in
the bottom of the tank. At this time the unit
will automatically begin pumping. The unit will
automatically shut off when full.
14. To empty a full tank by pumping, first remove
the vacuum hose from the liquid. Do not
empty liquid from hose back into tank. This
will cause the unit to overfill and misting will
occur through the exhaust port.
15. The ON switch must be manually held in
the ON position for approximately 10-15
seconds to allow the water level to be reduced
sufficiently, and then pumping will continue
automatically. The unit will continue to
discharge liquid until there is about 4" left in
the tank.
NOTE: Wet pick up volume is greater than
the discharge volume and step 15 may need
to be repeated if the
unit should shut off.
16. After wet pick up and pumping has been
completed, the remaining liquid should be
emptied from the tank and the pump pick up
assembly should be removed and cleaned.
17. To utilize your vacuum as non-pump, refer to
dry pick up operation for proper installation of
filters.
Operation (continued)
38
39
40 41
Portable Blower Operation (For
model 3VE22 only)
BLOWER SAFETY
1. Never operate the portable blower in wet or
damp conditions. Do not use in rain.
2. Keep area of operation clear of all persons,
particularly small children and pets.
3. Dress properly. Do not wear loose clothing
or jewelry. Always wear substantial footwear
and long pants. Secure loose hair with a
hat or hair net to avoid hair being caught in
moving parts.
4. Never blow debris in direction of bystanders.
5. Do not overreach or use blower from
unstable surface such as ladders, trees, steep
slopes, roof tops, etc. Always be sure of your
footing.
6. Inspect the area before using the blower.
Remove all debris and hard objects such as
rocks, glass, wire, etc. that can be blown or
cause damage during operation.
7. Always wear a respirator or face mask when
working in dusty environments.
8. Keep vents clean and clear of dirt and debris.
BLOWER ASSEMBLY
INSTRUCTIONS
1. To remove portable
blower from tank cover,
grasp both blower
handles and pull in an
upward motion
(Figure 42).
2. Insert 2½” extension
wand into the blower exhaust. Push firmly
into place by twisting wand slightly.
3. Attach desired accessory (Figure 43).
4. Plug the cord into an electrical outlet. Your
portable blower is ready for use. NOTE: If an
43
6