Dayton Model 4E769B heater is a 35,000 BTU/Hr construction heater. This heater
uses propane gas for combustion and electricity to run the motor. It is primarily
intended for temporary heating of buildings under construction, alteration, or
repair. This heater should only be used indoors but never in occupied dwellings.
®
Form 5S3439
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
4E769B
Version B - For Reduction G016.J
Fire, burn,
inhala-
tion, and explosion haz-
ard. Keep solid combus-
tibles such as building
materials, paper or card-
board, a safe distance
away from the heater as
recommended by the
instructions. Never use
the heater in spaces
which do or may contain
volatile or airborne com-
bustibles, or products
such as gasoline, sol-
vents, paint thinner, dust
particles, or unknown
chemicals.
Heater is designed and approved for use
as a construction heater under ANSI
Z83.7. The primary purpose of construc-
tion heaters is to provide temporary
heating of buildings under construction,
alteration or repair, and to provide
temporary emergency heat. Properly
used, the heater provides safe economi-
cal heating. Products of combustion are
vented into the area being heated.
We cannot foresee every use which may
be made of our heaters. Check with your
local fire safety authority if you have
questions about heater use.
Other standards govern the use of fuel
gases and heat producing products for
specific uses. Local authorities can advise
you about these.
Not for
home or
recreational vehicle use.
Unpacking
1. Remove all packing items applied to
heater for shipment. Keep plastic
cover caps (attached to inlet connec-
tor and hose/regulator assembly) for
storage.
2. Remove all items from carton.
3. Check all items for shipping damage.
If heater is damaged, promptly
inform dealer where you bought
heater.
GENERAL HAZARD
WARNING
Failure to comply with
the precautions and in-
structions provided with
this heater can result in
death, serious bodily
injury, and property loss
or damage from hazards
of fire, explosion, burn,
asphyxiation, carbon
monoxide poisoning, and/
or electrical shock.
Only persons who can
understand and follow
instructions should use or
service this heater.
If you need assistance or
heater information such
as an instructions
manual, labels, etc. con-
tact the manufacturer.
Figure 1 – Model 4E769B
Printed in U.S.A.
03430
1199/511/VCPVP
®
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - Construction Heater

Operating Instructions & Parts ManualDayton PropaneConstruction HeaterDescriptionDayton Model 4E769B heater is a 35,000 BTU/Hr construction heater

Seite 2

Dayton Operating Instructions and Parts Manual10Dayton PropaneConstruction Heater®4E769B4E769BFor Replacement Parts, call 1-800-323-062024 hours a day

Seite 3

Dayton Operating Instructions and Parts Manual11Model 4E769BVersion B - For Reduction G016.J®Dayton Operating Instructions and Parts Manual4E769BRepl

Seite 4

Dayton Operating Instructions and Parts Manual12Dayton PropaneConstruction Heater®4E769BNever attempt to service heater while it is connected to propa

Seite 5

Dayton Operating Instructions and Parts Manual13Model 4E769BVersion B - For Reduction G016.J®4E769BDescription Part No.10' Rubber Hose with Bras

Seite 6

Dayton Operating Instructions and Parts Manual14Dayton PropaneConstruction Heater®4E769BNotes_________________________________________________________

Seite 7

Dayton Operating Instructions and Parts Manual15Model 4E769BVersion B - For Reduction G016.J®4E769BNotes_____________________________________________

Seite 8

Dayton Operating Instructions and Parts Manual16Dayton PropaneConstruction Heater®4E769B101427-01Rev. B01/00Version B - For Reduction G016.J®LIMITED

Seite 9

Dayton Operating Instructions and Parts Manual2Dayton PropaneConstruction Heater®4E769BGeneral Safety InformationCarbon monoxidepoisoning may leadto d

Seite 10

Dayton Operating Instructions and Parts Manual3Model 4E769BVersion B - For Reduction G016.J®SpecificationsELECTRICAL SPECIFICATIONSElectricalInput Am

Seite 11 - Replacement Parts List

Dayton Operating Instructions and Parts Manual4Dayton PropaneConstruction Heater®4E769BProduct IdentificationFigure 2 – Model 4E769BShellHandleMotorPo

Seite 12

Dayton Operating Instructions and Parts Manual5Model 4E769BVersion B - For Reduction G016.J®Average Temperature Number of Tanks(oF) at Tank Location

Seite 13

Dayton Operating Instructions and Parts Manual6Dayton PropaneConstruction Heater®4E769BInstallationReview andunderstand thewarnings in the General Saf

Seite 14

Dayton Operating Instructions and Parts Manual7Model 4E769BVersion B - For Reduction G016.J®Operation (Continued)NOTE: If not opened slowly, excess-fl

Seite 15

Dayton Operating Instructions and Parts Manual8Dayton PropaneConstruction Heater®4E769BFigure 11 - Removing Motor and FanGuard from HeaterMaintenance

Seite 16

Dayton Operating Instructions and Parts Manual9Model 4E769BVersion B - For Reduction G016.J®IgnitorIgnitorMountingScrewRear HeadFigure 15 - Removing

Kommentare zu diesen Handbüchern

Keine Kommentare